Oasis 10-Gallon 12-Volt Continuous Duty Air Compressor - XDT10-4000-12

Save $269.70

Price:
Sale price$2,849.00 Regular price$3,118.70

Call Us Now for The Lowest Price: 430-888-4217
Free Shipping. No Sales Tax.

Handling Time:

Products ship in 1-2 Business Day.

Shipping Time:

Please allow 2-4 Business Days for Delivery.

Why Shop with Us?

☑ Fast Response & Service Times Add Peace of Mind for Your Business and Home.

☑ Friendly, Expert Staff Trusted By Hundreds of Homeowners & Business Owners

☑ SSL Secure Payment Gateway Make Shopping Easy and Stress-Free.

Description

Oasis 10-Gallon 12-Volt Continuous Duty Air Compressor - XDT10-4000-12

This system has been designed for commercial and industrial use. The new XDT-4000 features the XD4000 air compressor and is mounted on a 10 gallon ASME coded Tank. This package is designed for work trucks and tow trucks. For continued, extreme, and construction use, the XDT10 with fan cooled motor is recommended. These systems are completely factory assembled and tested, ready to bolt down and connect to the battery.

Specifications

Compressor Model

XD4000-12

Nominal Operating Voltage

12 Vdc

Dimensions
(L x W x H)

40" x 10" x 12"

Net Weight (Lbs)

110

Motor Type

Series Wound

Operating Temperature Range

-20℃ (-4℉) to 65℃ (150℉)

Max Pressure

200 psi

Max Restart Pressure

150 psi

Current at Max Pressure (200 psi)

≤190 amps

Flow Rate @ 100 psi

≥8 cfm

Duty Cycle @ 100psi @ 21 (70)

100% continuous

Typical Performance (cold, at sea level)

 

PSI CFM Current
0 15 110
50 10 140
100 9 170

Flow rate decreases as operating temperature and/or altitude increase.

Downloads

Oasis Air Compressor Owners Manual

Do I Need a Tank?

Oasis compressors can be used either with or without a tank, depending on your application. Our compressors are capable of running a 1/2″ impact wrench without a tank under the following conditions:

  • Apply adequate power to the compressor per our Power Addendum
  • Use a tool that makes efficient use of compressed air (the Ingersoll-Rand IR231 & 2135Ti guns work very well)
  • Use proper trigger technique, pull the trigger in two second bursts.

We have tested our compressors under these conditions, they are able to tighten 9/16″ lug nuts to over 160 ft/lbs without a tank. We are happy to help you determine the best system for your needs. Please call us for tech support!

Pressure Up Rates

Tank Size Pressure Min:Sec 12vdc Min:Sec 24vdc
5 Gallon 0-150 psi 0:54 0:51
5 Gallon 120-150 psi 0:11 0:10
10 Gallon 0-150 psi 1:47 1:40
10 Gallon 120-150 psi 0:22 0:20

WHAT'S THE PURPOSE OF AN AIR TANK?

A tank is a storage chamber which holds a reserve of pressurized air. When running an air tool for example, air is taken from the tank to run the tool.  As pressure in the tank drops, a pressure switch turns a compressor on to re-pressurize the tank.  It works the same way that an alternator recharges a battery after power is used from it.

A Tank Will…

  • Allow the compressor to run fewer cycles, minimizing the stress on the compressor and increasing life expectancy.
  • Support the use of some air tools with a high air consumption rate that would otherwise not be possible. Alone, the Oasis compressors will run ½” impact wrenches, but the use of ¾” or larger impact wrenches, die grinders, sanders, etc. require a tank.

A Tank Will Not…

  • Increase or decrease the workload of a compressor to do a job. If you take air out of a tank and put it in a tire, the compressor must work the same amount as it would if you had no tank at all.
  • Allow tires to be inflated any faster than an Oasis compressor can do alone. A tank will slightly reduce the inflation time of other slower compressors, but Oasis compressors are so efficient that a tank doesn’t make any difference.

A More Efficient System

Compared to systems that require multiple compressors to meet a high demand for air, our superior performance makes it possible to meet the needs of your application with a much simpler system.

By keeping your system simple, you will have higher performance and better reliability. With fewer components, there are fewer problems, leaks, and difficulty. Less is more.

AIR COMPRESSOR INSTALLATION PROCEDURE

Air compressor installation is pretty straightforward; however, it’s important to understand the basics regarding the capacity of your compressor, the tools and materials you’ll require for installation, and the proper installation procedure.

Position Your Compressor

Choose the proper location to position your compressor. Oasis compressors are small and can be mounted almost anywhere, including in a truck bed, in a ventilated trunk, in a storage compartment of a utility truck, under a service truck, on the front bumper of an off-road vehicle, on a detachable mount, or to the chassis of a vehicle.

Provide Adequate Space and Protection


Ensure you have enough room for your operations and tool applications. Your compressor should also be shielded from contaminants and the elements to ensure optimal performance. If you mount your compressor to the chassis of a vehicle, be sure to protect it with a splash guard to keep road muck and debris off the compressor.

Provide Adequate Power

The shorter your power cables, the better your compressor will perform. Mounting an isolated auxiliary battery next to the compressor and cutting the cables down to minimum length will provide maximum performance. Use a deep cycle battery. Absorbed Glass Mat (AGM) batteries work extremely well for this application and are highly recommended. If you must mount the compressor farther away than the 10’ power cables will allow, use larger diameter cable instead of #4AWG cable provided. Be sure your charging system is in top condition, and all connections are clean and secure. Some applications may require an upgrade to the charging system and/or multiple batteries.

Choose Proper Components

Now that your compressor is in the proper position, it’s time to select and install the required fittings and hose lengths for your specific application. Install a high temperature air line (a stainless steel braided, teflon lined hose is recommended) from the discharge port in the head of the compressor to a tank or point of use fitting. Install a pressure switch rated at 200 psi or less, on the tank (if using one) or air line (if not) coming from compressor, to automatically control the compressor as pressure is used from the system (refer to the owner’s manual for a wiring diagram that shows how to connect the pressure switch, and a dash mounted switch if desired, to the compressor’s control module).

Stabilize the Compressor

To prevent damage and minimize the sound level coming from the compressor, you can reduce vibration levels by placing it on isolator pads.

Check Owner’s Manual

Once you’ve implemented the proper components, consult the owner’s manual for a wiring diagram, and to determine the right start-up procedure.

Power On and Activate Tools

Once you understand the correct start-up procedure for your compressor, you can power it on and activate your pneumatic tools.

FACTORS TO CONSIDER

To ensure that your compressor will run smoothly and efficiently, consider the following factors:

  • Ventilation. Compressors generate high levels of heat, so it’s important to install your compressor in an area with proper ventilation and airflow. Mounting inside the engine compartment or near exhaust components is NOT recommended.
  • Service access. Install or mount your compressor in a location with adequate access for maintenance such as checking the oil and replacing the filter element. You can measure your floor space and doorways to ensure the compressor will have proper clearance.
  • Mount to a sturdy surface. To prevent damage, make sure you horizontally mount your compressor to a flat and stable surface.
  • Under vehicle installation. When mounting your compressor under a vehicle, fabricate a splash guard to protect it from mud, dirt, and other road debris, and remotely locate the intake filter to a dry location with a length of hose.
  • Protect from salt. If your compressor will be operating in a marine environment or in an area where roads are salted for the winter, use our Fluid Film™ on the commutator and motor brushes as preventative maintenance.
  • Sufficient power. To prevent the motor from shutting off, stalling, or burning up, make sure your compressor has access to and receives sufficient power.
  • Safety. Use an appropriate safety valve to protect all the components of your compressed air system. Also, make sure you use the proper fuses.
Payment & Security
American Express Apple Pay Diners Club Discover Meta Pay Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed